Related Experiment Video
Updated: Feb 4, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
A density assignment method for dose monitoring in head-and-neck radiotherapy
A Barateau1, N Perichon2, J Castelli2
1Univ Rennes, CLCC Eugène Marquis, INSERM, LTSI - UMR 1099, F-35000, Rennes, France. anais.barateau@gmail.com.
Background And Purpose:
During head-and-neck (H&N) radiotherapy, the parotid glands (PGs) may be overdosed; thus, a tool is required to monitor the delivered dose. This study aimed to assess the dose accuracy of a patient-specific density assignment method (DAM) for dose calculation to monitor the dose to PGs during treatment.
Patients And Methods:
Forty patients with H&N cancer received an intensity modulated radiation therapy (IMRT), among whom 15 had weekly CTs. Dose distributions were calculated either on the CTs (CTref), on one-class CTs (1C-CT, water), or on three-class CTs (3C-CT, water-air-bone). The inter- and intra-patient DAM uncertainties were evaluated by the difference between doses calculated on CTref and 1C-CTs or 3C-CTs. PG mean dose (Dmean) and spinal cord maximum dose (D2%) were considered. The cumulated dose to the PGs was estimated by the mean Dmean of the weekly CTs.
Results:
The mean (maximum) inter-patient DAM dose uncertainties for the PGs (in cGy) were 23 (75) using 1C-CTs and 12 (50) using 3C-CTs (p ≤ 0.001). For the spinal cord, these uncertainties were 118 (245) and 15 (67; p ≤ 0.001). The mean (maximum) DAM dose uncertainty between cumulated doses calculated on CTs and 3C-CTs was 7 cGy (45 cGy) for the PGs. Considering the difference between the planned and cumulated doses, 53% of the ipsilateral and 80% of the contralateral PGs were overdosed by +3.6 Gy (up to 8.2 Gy) and +1.9 Gy (up to 5.2 Gy), respectively.
Conclusion:
The uncertainty of the three-class DAM appears to be clinically non-significant (<0.5 Gy) compared with the PG overdose (up to 8.2 Gy). This DAM could therefore be used to monitor PG doses and trigger replanning.
Related Concept Videos
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Dose Size and Dosing Frequency: Determination Methods
Muscles of the Anterior Neck
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses