Related Experiment Video
Updated: Feb 4, 2026

Isolation of Retinal Arterioles for Ex Vivo Cell Physiology Studies
Published on: July 14, 2018
Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A
William Jones Dartora1, Marcelo Krieger Maestri2, Maria Inês Schmidt3
1MSc. Doctoral Student, Postgraduate Program on Epidemiology, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre (RS), Brazil.
Background:
Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders.
Design And Setting:
Cross-sectional study at six teaching and research institutions.
Methods:
To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed.
Results:
Mean differences between ELSA-Brasil and gold-standard readings were 0.16 µm (95% CI -0.17-0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 µm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55-0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55-0.82) for AVR.
Conclusions:
Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil.
Related Concept Videos
Cross-Sectional Research
Venules
Venules are much smaller in diameter compared to their larger counterparts, the veins. They are generally 8 to 100 micrometers in diameter, significantly smaller than the size of veins. The walls of venules are thin, consisting of the endothelium, a thin layer of connective tissue, and occasionally a few smooth muscle cells. This structural simplicity is a stark contrast...
Finding Volume Using Cross-Sectional Area
Profile Leveling and Cross Sections
Reliability and Validity
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs