Related Experiment Video
Updated: Feb 4, 2026

Solubilization and Bio-conjugation of Quantum Dots and Bacterial Toxicity Assays by Growth Curve and Plate Count
Published on: July 11, 2012
An Electrochemical Cholesterol Biosensor Based on A CdTe/CdSe/ZnSe Quantum Dots-Poly (Propylene Imine) Dendrimer
Kefilwe Vanessa Mokwebo1, Oluwatobi Samuel Oluwafemi2,3, Omotayo Ademola Arotiba4,5
1Department of Applied Chemistry, University of Johannesburg, P.O. Box 17011, Doornfontein 2028, Johannesburg, South Africa. kvmokwebo@gmail.com.
Abstract:
We report the preparation of poly (propylene imine) dendrimer (PPI) and CdTe/CdSe/ZnSe quantum dots (QDs) as a suitable platform for the development of an enzyme-based electrochemical cholesterol biosensor with enhanced analytical performance. The mercaptopropionic acid (MPA)-capped CdTe/CdSe/ZnSe QDs was synthesized in an aqueous phase and characterized using photoluminescence (PL) spectroscopy, ultraviolet-visible (UV-Vis) spectroscopy, transmission electron microscopy (TEM), X-ray power diffraction (XRD), energy dispersive X-ray (EDX) spectroscopy. The absorption and emission maxima of the QDs red shifted as the reaction time and shell growth increased, indicating the formation of CdTe/CdSe/ZnSe QDs. PPI was electrodeposited on a glassy carbon electrode followed by the deposition (by deep coating) attachment of the QDs onto the PPI dendrimer modified electrode using 1-Ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC), and N-hydroxysuccinimide (NHS) as a coupling agent. The biosensor was prepared by incubating the PPI/QDs modified electrode into a solution of cholesterol oxidase (ChOx) for 6 h. The modified electrodes were characterized by voltammetry and impedance spectroscopy. Since efficient electron transfer process between the enzyme cholesterol oxidase (ChOx) and the PPI/QDs-modified electrode was achieved, the cholesterol biosensor (GCE/PPI/QDs/ChOx) was able to detect cholesterol in the range 0.1⁻10 mM with a detection limit (LOD) of 0.075 mM and sensitivity of 111.16 μA mM-1 cm-2. The biosensor was stable for over a month and had greater selectivity towards the cholesterol molecule.
Related Concept Videos
Quantum Numbers
The Quantum-Mechanical Model of an Atom
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Cholesterol: Significance and Regulation
Considering cholesterol and...
The Dot Product
Dot Product
In engineering, the dot product of any two vectors is the product of the magnitudes of the vectors and the cosine of the angle between them. It is denoted by a dot symbol between the two vectors.
Consider a vehicle pulling an object along the ground using a rope. If the rope makes an angle with the horizontal axis, the work done can be calculated using the dot product of the force applied and the object's displacement.
The dot...

