Application of Stable Isotope Dilution and Liquid Chromatography Tandem Mass Spectrometry for Multi-Mycotoxin
1U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, 5001 Campus Dr, College Park, MD 20740.
Abstract:
Background: Mycotoxin contamination in oils remains an important food safety issue. To monitor the occurrence of mycotoxins in edible oils, it is important to develop analytical methods that can determine multiple mycotoxins in oil products. A stable isotope dilution LC-tandem MS (LC-MS/MS) method for the simultaneous determination of 12 mycotoxins in five edible oil matrixes (canola, corn, olive, peanut, and soybean oil) was developed and validated. Methods: Prior to extraction, the oil samples were fortified with ¹³C uniformly labeled internal standards (¹³C-IS) for 12 target mycotoxins, followed by extraction and LC-MS/MS analysis. Quantitation was achieved using solvent-only calibration standards, relative response factors of ¹³C-IS, and target mycotoxins. Results: The majority of recoveries in oil for ochratoxin A and aflatoxins B1, B2, G1, and G2 fortified at 1, 10, and 100 ng/g as well as deoxynivalenol; fumonisins B1, B2, and B3; T-2 toxin; HT-2 toxin; and zearalenone fortified at 10, 100, and 1000 ng/g ranged from 80 to 120% with RSDs of <20%. The method LOQs ranged from 0.1 ng/g (aflatoxin B1) to 6.4 ng/g (zearalenone). Among 16 U.S. market samples, zearalenone was detected in three corn oil samples at 37, 185, and 317 ng/g, respectively. T-2 toxin was found in two corn oil samples at 7 and 10 ng/g, respectively. Conclusions: The method provides sufficient selectivity, sensitivity, accuracy, and repeatability to screen edible oils for regulated mycotoxins such as aflatoxins at low nanogram per gram concentrations without using conventional standard addition or matrix-matched calibration standards to correct for matrix effects.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Tandem Mass Spectrometry
Mass Spectrometry: Isotope Effect
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Isotopes
An element's atomic mass, or weight,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...