Automatic segmentation of cardiac substructures from noncontrast CT images: accurate enough for dosimetric analysis?
Yangkun Luo1,2, Yujin Xu1,3, Zhongxing Liao1
1a Department of Radiation Oncology , The University of Texas MD Anderson Cancer Center , Houston , TX , USA.
Purpose:
We evaluated the feasibility of using an automatic segmentation tool to delineate cardiac substructures from noncontrast computed tomography (CT) images for cardiac dosimetry and toxicity analyses for patients with nonsmall cell lung cancer (NSCLC) after radiotherapy.
Material And Methods:
We used an in-house developed multi-atlas segmentation tool to delineate 11cardiac substructures, including the whole heart, four heart chambers, and six greater vessels, automatically from the averaged 4D-CT planning images of 49 patients with NSCLC. Two experienced radiation oncologists edited the auto-segmented contours. Times for automatic segmentation and modification were recorded. The modified contours were compared with the auto-segmented contours in terms of Dice similarity coefficient (DSC) and mean surface distance (MSD) to evaluate the extent of modification. Differences in dose-volume histogram (DVH) characteristics were also evaluated for the modified versus auto-segmented contours.
Results:
The mean automatic segmentation time for all 11 structures was 7-9 min. For the 49 patients, the mean DSC values (±SD) ranged from .73 ± .08 to .95 ± .04, and the mean MSD values ranged from 1.3 ± .6 mm to 2.9 ± 5.1 mm. Overall, the modifications were small; the largest modifications were in the pulmonary vein and the inferior vena cava. The heart V30 (volume receiving dose ≥30 Gy) and the mean dose to the whole heart and the four heart chambers were not different for the modified versus the auto-segmented contours based on the statistically significant condition of p < .05. Also, the maximum dose to the great vessels was no different except for the pulmonary vein.
Conclusions:
Automatic segmentation of cardiac substructures did not require substantial modifications. Dosimetric evaluation showed no significant difference between the auto-segmented and modified contours for most structures, which suggests that the auto-segmented contours can be used to study cardiac dose-responses in clinical practice.
More Related Videos
08:39High-throughput Image Analysis of Tumor Spheroids: A User-friendly Software Application to Measure the Size of Spheroids Automatically and Accurately
Published on: July 8, 2014
10:25Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Automatic Processing and Automatic Social Behavior
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...