Related Experiment Video
Updated: Feb 4, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
The Effect of LVAD Pressure Sensitivity on the Assisted Circulation Under Consideration of a Mitral Insufficiency: An
Roland Graefe1, Christof Beyel1, Andreas Henseler1
1ReinVAD GmbH, Aachen, Germany.
Abstract:
Current left ventricular assist devices (LVADs) differ with respect to their pump characteristics as described by the pump characteristic curve (also called HQ-curve). Pressure sensitive LVADs depict a flat characteristic curve while most available LVADs have a steep, less pressure sensitive characteristic curve. This in vitro study investigated the effect of LVAD pressure sensitivity with a focus on the afterload of the right ventricle (RV) which is one out of many factors influencing right heart failure (RHF). To this end, two laboratory pumps differing in pressure sensitivity were tested as LVAD in an established, active mock circulation loop (MCL). The MCL represented patients with left heart failure and mitral insufficiency as another contributing factor to RV afterload. The results show that the pressure-volume loop (PV-loop) of the left ventricle (LV) undergoes a leftward and thus somewhat of a downward-shift for highly pressure sensitive support. Consequently, the LV is unloaded to a higher degree at comparable arterial blood pressure and identical cardiac output, pulmonary and systemic vascular resistance and ventricular contractility. This causes a concomitant decrease of RV afterload. This effect seems to be due to increased unloading during systole. In case of a severe concomitant mitral insufficiency and looking at left atrial pressure, the difference is 18.5%. Without mitral insufficiency, the difference is reduced to 10.2%.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test
Design Consideration
The factor of safety is another key...
Mitral Stenosis I: Introduction