Related Experiment Video
Updated: Feb 4, 2026

Author Spotlight: Optimization of Performance Parameters of the TAGGG Telomere Length Assay
Published on: April 21, 2023
Optimizing Wavelet ECG Watermarking to Maintain Measurement Performance According to Industrial Standard
Agnieszka Świerkosz1, Piotr Augustyniak2
1Department of Biocybernetics and Biomedical Engineering, AGH University of Science and Technology, 30 Mickiewicz Ave, 30-059 Krakow, Poland. aswierk@agh.edu.pl.
Abstract:
Watermarking is currently investigated as an efficient and safe method of embedding additional patient or environment-related data into the electrocardiogram. This paper presents experimental work on the assessment of the loss of ECG (electrocardiogram signal) diagnostic quality from the industrial standard EN60601-2-25:2015 point of view. We implemented an original time-frequency watermarking technique with an adaptive beat-to-beat lead-independent data container design. We tested six wavelets, six coding bit depth values (including the automatic noise-dependent one) and two types of watermark content to find the conditions that are necessary for watermarked ECG to maintain the compliance with International Electrotechnical Commission (IEC) requirements for interpretation performance. Unlike other authors, we did not assess the differences of signal values, but errors in ECG wave delineation results. The results of a total of 7300 original and watermarked 10 s ECGs were statistically processed to reveal possible interpretation quality degradation due to watermarking. Finally we found (1) the Symlet of 11-th order as the best of the wavelets that were tested; (2) the important role of ECG wave delineation and noise tracking procedures; (3) the high influence of the watermark-to-noise similarity of amplitude and values distribution and (4) the stability of the watermarking capacity for different heart rates in atrial rhythms.
More Related Videos
07:22Standardized Method for Measuring Collection Efficiency from Wipe-sampling of Trace Explosives
Published on: April 10, 2017
08:08Using Wavelet Entropy to Demonstrate how Mindfulness Practice Increases Coordination between Irregular Cerebral and Cardiac Activities
Published on: May 10, 2017
Related Concept Videos
Measurement: Standard Units
Units and Standards of Measurement
Measurements of physical quantities are...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Microorganisms in Agriculture and Food industry
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Standard Electrode Potentials