Paper-based graphene oxide biosensor coupled with smartphone for the quantification of glucose in oral fluid
Yuan Jia1,2, Hao Sun3,4, Xiao Li1,2
1School of Mechanical Engineering, Southeast University, Nanjing, 211189, China.
Abstract:
Rapid, disposable, point-of-care (POC) oral fluid testing has gained considerable attention in recent years as saliva contains biomarker and components of the serum proteome that offer important information on both oral and systemic disease. Microfluidic paper-based analytical devices (μPADs) coupled with smartphone reflectance sensing systems have long been considered to be an effective POC tool for the diagnostics of biomarkers in oral fluid. However, the existing portable systems are limited by the poor color distribution in the detection area as well as not being universally applicable. Therefore, using the properties of nanomaterials to our advantage, we present a simple, universally applicable approach that features graphene oxide (GO) coated μPADs coupled with smartphone-based colorimetric detection for the direct quantification of glucose. An integrated portable system is used to implement the approach. Owing to the enhanced reagents absorptivity, reactive efficiency and homogeneity of color distribution from the deposition of GO, the glucose assay performance was improved. Also, by using a self-developed app, the glucose concentrations in physiological range can be automatically quantified. Finally, the approach is universally applicable as the modification of μPADs with GO can be achieved without the use of any linker, binder or retention aid, which avoids possible enzyme cross contamination. The system was first calibrated by standard glucose buffer solutions, and the limit of detection as well as the linear dynamic range were found to be 0.02 mM and 0~1 mM, respectively, which are appropriate for analyzing glucose concentrations in a clinically relevant range. Finally, the system was used for quantifying glucose concentrations in artificial saliva and the results obtained using our portable system showed reasonable agreement with the actual use concentrations. Thus, the utility of the system in sensitively quantifying glucose concentrations in a portable, and repeatable manner is demonstrated.
More Related Videos
Related Concept Videos
Oxidation Numbers
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...


