Modular endoprosthetic implant for maximizing residual limb length: A case report
Marc El Beaino1, Jiayong Liu2, Patrick P Lin1
11 Department of Orthopaedic Oncology, MD Anderson Cancer Center, Houston, TX, USA.
Background::
For transfemoral amputations, the residual femoral length is critically important to prosthetic function. The aim of this report is to describe a novel method of extending femoral length and to assess its stability over time.
Case Description And Methods::
A 57-year-old woman with recurrent parosteal osteosarcoma was treated with above-knee amputation. A portion of the distal femoral endoprosthesis, which included uncemented fixation with a Compress® stem, was retained in an effort to extend the short femoral remnant and maximize stump length.
Findings::
At 3 years follow-up, the Compress stem remained well-fixed, and there was no soft tissue breakdown over the implant. The patient ambulated with a prosthetic limb and no external support.
Outcomes And Conclusion::
To the best of our knowledge, this is the first report of using the Compress device as a means to maintain stable fixation and extend residual femoral length following above-knee amputation.
Clinical Relevance:
Extension of residual bone length in amputated limbs can help improve prosthetic fitting and function. The Compress device may be useful in this application as a means of secure fixation for a modular metallic prosthesis.
More Related Videos
14:18Taking the Next Step: a Neural Coaptation Orthotopic Hind Limb Transplant Model to Maximize Functional Recovery in Rat
Published on: August 30, 2020
06:28Standardized Modular Assembly of Polycistronic Operons with Modular Cloning (MoClo) using the In-Cloning toolkit
Published on: September 2, 2025
Related Concept Videos
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses
Residual Stresses in Circular Shafts
Residual Stresses in Bending
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Data Reporting and Recording