Related Experiment Video
Updated: Feb 3, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Differences in scar lesion formation between radiofrequency and cryoballoon in atrial fibrillation ablation: a
Ricardo Ruiz-Granell1, Gabriel Ballesteros2, David Andreu3
1Arrhythmia Unit, Department of Cardiology, Hospital Clínico Universitario, Av. Blasco Ibañez, 17, Valencia, Spain.
Aims:
Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is usually associated to conduction gaps in pulmonary veins (PVs). Our objective was to characterize gaps in patients with recurrences after a first radiofrequency (RF) or cryoballoon (CB) PVI procedure, using a high-density mapping (HDM) system.
Methods And Results:
Fifty patients with AF recurrence after a first PVI procedure (pre-RF 25 patients; pre-CB 25 patients) were included at two centres. Activation map (AM) and voltage map (VM) of the left atrium and PVs were built using the HDM Rhythmia® system. Superior PVs were reconnected more frequently in both groups. Right PVs were reconnected more frequently in pre-RF patients. Pre-RF patients had more reconnected veins than pre-CB patients (mean ± standard deviation: 3.00 ± 0.96 vs. 1.88 ± 1.13; P < 0.001) and more gaps (4.84 ± 2.06 vs. 2.16 ± 1.49; P < 0.001). Gaps in the VM were wider in pre-CB patients (16.5 ± 9.5 mm vs. 12.1 ± 4.8 mm; P = 0.006). There was a gap in 179 of the 800 PV segments analysed (22%); 52% were identified in both AM and VM maps; 39% only in the AM and 8% only in the VM. The highest sensitivity and specificity for gap detection was obtained with VM in pre-CB patients and with AM in pre-RF patients.
Conclusion:
In conclusion, HDM seems to be a useful and precise tool to detect conduction gaps after a first PVI procedure. The anatomical pattern and location of gaps depends on the technique used previously, usually being multiple, smaller, and better detected by AM after RF, and fewer, wider, and better detected by VM after CB.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...