A Spatiotemporal-Constrained Sorting Method for Motion-Robust 4D-MRI: A Feasibility Study
Chunhao Wang1, Ergys Subashi1, Fang-Fang Yin1
1Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina.
Purpose:
To develop a spatiotemporal-constrained sorting technique for motion-robust 4 dimensional-magnetic resonance imaging.
Methods And Materials:
This sorting method implemented 2 new approaches for 4-dimensional imaging: (1) an optimized sparse k-space acquisition trajectory with self-gating signal derivation, and (2) a retrospective k-space sorting for reconstruction using a novel spatiotemporal-constrained strategy to minimize breathing variation-induced motion artifacts. Such sorting was regularized by a spatiotemporal index. Volumetric reconstruction was implemented iteratively with a secnd-order total generalized variation penalty. The proposed method was evaluated and compared with the conventional phase-sorting and amplitude-sorting methods in 2 studies. In a computer simulation study, 6 abdominal motion scenarios, including 2 cosine and 4 patient breathing motion patterns, were studied. Reconstruction accuracy was evaluated quantitatively in reference to the ground truth by average image relative error (IRE) in 10 phases and target Dice similarity coefficients (DSCs) in end-of-exhalation/inhalation phases. In addition, the proposed method was evaluated using a custom-made motion phantom. Reconstruction accuracy was evaluated by motion range measurement and image quality comparison in both fast and slow breathing motions.
Results:
In the simulation study, stitching motion artifacts in restricted images were lessened using the proposed method compared with those using the conventional methods. The average IRE and target DSC (end-of-exhalation/inhalation) were 0.031 and 0.95/0.94, respectively, suggesting better motion reconstruction accuracy than the phase-sorted method (IRE, 0.057; DSC, 0.89/0.89) and the amplitude-sorted method (IRE, 0.048; DSC, 0.91/0.88). In the phantom study, the moving target reconstructed by the proposed method demonstrated better rendering with less edge blurring. With fast breathing motion, the range measured using the proposed method was more accurate than that of the phase-sorted method and was comparable to the result of amplitude-sorted method and ground truths.
Conclusions:
Preliminary results suggested that the proposed sorting technique could reconstruct high-quality images and accurate motion estimation with reduced artifacts in 4 dimensional-magnetic resonance imaging.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Equation of Motion: General Plane motion - Problem Solving
The friction between the roller and the ground is characterized by two coefficients. The static friction coefficient is 0.15, while the kinetic friction coefficient is 0.1. These values are crucial in understanding the interaction between...
Projectile Motion: Example
When we speak of the range (R) of a projectile on...
Mitochondrial Protein Sorting
Most of these mitochondrial proteins are encoded by the nucleus and imported to the mitochondria as unfolded or loosely folded precursors. Mitochondrial precursors...