Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion:
Sarah Feger1, Carsten Kendziorra1, Steffen Lukas1
1Department of Radiology, Charité-Universitätsmedizin Berlin, Berlin, Germany.
Purpose:
Myocardial computed tomography perfusion (CTP) allows the assessment of the functional relevance of coronary artery stenosis. This study investigates to what extent the contour sharpness of sequences acquired by dynamic myocardial CTP is influenced by the following noise reduction methods: temporal averaging and adaptive iterative dose reduction 3D (AIDR 3D).
Materials And Methods:
Dynamic myocardial CT perfusion was conducted in 29 patients at a dose level of 9.5±2.0 mSv and was reconstructed with both filtered back projection (FBP) and strong levels of AIDR 3D. Temporal averaging to reduce noise was performed as a post-processing step by combining two, three, four, six and eight original consecutive 3D datasets. We evaluated the contour sharpness at four distinct edges of the left-ventricular myocardium based on two different approaches: the distance between 25% and 75% of the maximal grey value (d) and the slope in the contour (m).
Results:
Iterative reconstruction reduced contour sharpness: both measures of contour sharpness performed better for FBP than for AIDR 3D (d = 1.7±0.4 mm versus 2.0±0.5 mm, p>0.059 at all edges; m = 255.9±123.9 HU/mm versus 160.6±123.5 HU/mm; p<0.023 for all edges). Increasing levels of temporal averaging degraded contour sharpness. When FBP reconstruction was applied, contour sharpness was best without temporal averaging (d = 1.7±0.4 mm, m = 255.9±123.9 HU/mm) and poorest for the strongest levels of temporal averaging (d = 2.1±0.3 mm, m = 142.2±104.9 HU/mm; comparison between lowest and highest temporal averaging level: for d p>0.052 at all edges and for m p<0.001 at all edges).
Conclusion:
The use of both temporal averaging and iterative reconstruction degrades objective contour sharpness parameters of dynamic myocardial CTP. Thus, further advances in image processing are needed to optimise contour sharpness of 4D myocardial CTP.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
10:56Procurement and Perfusion-Decellularization of Porcine Vascularized Flaps in a Customized Perfusion Bioreactor
Published on: August 1, 2022
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...