Related Experiment Video
Updated: Feb 3, 2026

Pupillary Response as Assessment of Effective Seizure Induction by Electroconvulsive Therapy
Published on: April 11, 2019
The relationship between seizure in electroconvulsive therapy and pupillary response using an automated pupilometer
Kazuhiro Shirozu1, Keitaro Murayama2, Yuji Karashima3
1Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. shiron@kuaccm.med.kyushu-u.ac.jp.
Objectives:
Seizure duration and morphology, postictal suppression, and sympathetic nervous system activation are all recommended as assessments of adequate seizure in electroconvulsive therapy (ECT). However, blood pressure and heart rate are not typically assessed as part of sympathetic nervous system activation because of the administration of anesthetic or cardiovascular agents during ECT. Although the pupils are known to reflect to the activity of autonomic nervous system and the degree of brain damage, previous studies have not examined the relationship between seizure of electroconvulsive therapy and pupillary response.
Methods:
We conducted 98 sessions of ECT with 13 patients, divided into two groups according to seizure quality: (1) adequate or (2) inadequate. Pupillary light reflex [% constriction = (maximum resting pupil size {MAX} - minimum pupil size after light stimulation)/MAX × 100] was measured using a portable infrared quantitative pupilometer before anesthesia induction and immediately after electrical stimulation.
Results:
The number regarded as adequate was 67 times and as inadequate was 31 times. Maximum pupil size at the control and immediately after electrical stimulation was similar between the adequate and inadequate groups. Pupillary light reflex was similar at the control between both groups, but significantly smaller immediately after stimulation in the adequate group (2.5 ± 3.6%) compared with the inadequate group (10.6 ± 11.5%). Receiver operating characteristic curve analysis revealed that pupillary light reflex (> 5.5%) predicted adequate seizure.
Conclusions:
The current findings suggest that pupillary constriction immediately after ECT could provide a helpful method for assessing the efficacy of ECT.
More Related Videos
09:07Electroconvulsive Seizures in Rats and Fractionation of Their Hippocampi to Examine Seizure-induced Changes in Postsynaptic Density Proteins
Published on: August 15, 2017
09:34An Automated Culture System for Use in Preclinical Testing of Host-Directed Therapies for Tuberculosis
Published on: August 16, 2021
Related Concept Videos
Electroconvulsive Therapy
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dose-Response Relationship: Selectivity and Specificity
Relationship Formation
Ending Relationships