Retinal imaging with optical coherence tomography and low-loss adaptive optics using a 2.8-mm beam size
Reddikumar Maddipatla1,2, Joel Cervantes1,3, Yukitoshi Otani1,4
1Center for Optical Research and Education, Utsunomiya University, Utsunomiya, Japan.
Abstract:
As data acquisition for retinal imaging with optical coherence tomography (OCT) becomes faster, efficient collection of photons becomes more important to maintain image quality. One approach is to use a larger aperture at the eye's pupil to collect more photons that have been reflected from the retina. A 2.8-mm beam diameter system with only seven reflecting surfaces was developed for low-loss retinal imaging. The larger beam size requires defocus and astigmatism correction, which was done in a closed loop adaptive optics method using a Shack-Hartmann wavefront sensor and a deformable mirror (DM) with 140 actuators and a ±2.75 μm stroke. This DM facilitates defocus correction ranging from approximately -3 D to +3 D. Comparing the new system with a standard 1.2-mm system on a model eye, a signal-to-noise gain of 4.5 dB and a 2.3 times smaller speckle size were measured. Measurements on the retinas of five subjects showed even better results, with increases in dynamic range up to 13 dB. Note that the new sample arm only occupies 30 cm × 60 cm, which makes it highly suitable for imaging in a clinical environment. Figure: B-scan images obtained over a width of 8 deg from the right eye of a 31-year-old Caucasian male. While the left side was imaged with a standard 1.2-mm OCT system, the right side was imaged with the 2.8-mm system. Both images were collected with the same integration time and incident power, after correction of aberrations. Using the dynamic range within the images, which is determined by comparing the highest pixel value to the noise floor, a difference in dynamic range of 10.8 dB was measured between the two systems.
Related Concept Videos
Adaptations that Reduce Water Loss
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Properties of Enantiomers and Optical Activity
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...