Related Experiment Video
Updated: Feb 3, 2026

Analysis of SEC-SAXS data via EFA deconvolution and Scatter
Published on: January 28, 2021
CLIPick: a sensitive peak caller for expression-based deconvolution of HITS-CLIP signals
Sihyung Park1, Seung Hyun Ahn2, Eun Sol Cho1
1Division of Life Sciences, College of Life Sciences and Biotechnology, Korea University, Seoul 02841, Korea.
Abstract:
High-throughput sequencing of RNAs isolated by crosslinking immunoprecipitation (HITS-CLIP, also called CLIP-Seq) has been used to map global RNA-protein interactions. However, a critical caveat of HITS-CLIP results is that they contain non-linear background noise-different extent of non-specific interactions caused by individual transcript abundance-that has been inconsiderately normalized, resulting in sacrifice of sensitivity. To properly deconvolute RNA-protein interactions, we have implemented CLIPick, a flexible peak calling pipeline for analyzing HITS-CLIP data, which statistically determines the signal-to-noise ratio for each transcript based on the expression-dependent background simulation. Comprising of streamlined Python modules with an easy-to-use standalone graphical user interface, CLIPick robustly identifies significant peaks and quantitatively defines footprint regions within which RNA-protein interactions were occurred. CLIPick outperforms other peak callers in accuracy and sensitivity, selecting the largest number of peaks particularly in lowly expressed transcripts where such marginal signals are hard to discriminate. Specifically, the application of CLIPick to Argonaute (Ago) HITS-CLIP data were sensitive enough to uncover extended features of microRNA target sites, and these sites were experimentally validated. CLIPick enables to resolve critical interactions in a wide spectrum of transcript levels and extends the scope of HITS-CLIP analysis. CLIPick is available at: http://clip.korea.ac.kr/clipick/.
More Related Videos
Related Concept Videos
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...
IR Spectrum Peak Intensity: Dipole Moment
Bacterial Signaling

