Effects of Cooling on the SNR and Contrast Detection of a Low-Light Event-Based Camera
Abstract:
Johnson-Nyquist noise is the electronic noise generated by the thermal agitation of charge carriers, which increases when the sensor overheats. Current high-speed cameras used in low-light conditions are often cooled down to reduce thermal noise and increase their signal to noise ratio. These sensors, however, record hundreds of frames per second, which takes time, requires energy, and heavy computing power due to the substantial data load. Event-based sensors benefit from a high temporal resolution and record the information in a sparse manner. Based on an asynchronous time-based image sensor, we developed another version of this event-based camera whose pixels were designed for low-light applications and added a Peltier-effect-based cooling system at the back of the sensor in order to reduce thermal noise. We show the benefits from thermal noise reduction and study the improvement of the signal to noise ratio in the estimation of event-based normal flow norm and angle and particle tracking in microscopy.
More Related Videos
09:52How to Find Effects of Stimulus Processing on Event Related Brain Potentials of Close Others when Hyperscanning Partners
Published on: May 31, 2018
12:00Investigating the Effects of Antipsychotics and Schizotypy on the N400 Using Event-Related Potentials and Semantic Categorization
Published on: November 19, 2014
Related Concept Videos
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Light Acquisition
Integration of Synaptic Events