Related Experiment Video
Updated: Feb 3, 2026

Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
Published on: May 15, 2013
Lung volumes, respiratory mechanics and dynamic strain during general anaesthesia
D L Grieco1, A Russo1, B Romanò1
1Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Fondazione "Policlinico Universitario A. Gemelli", Rome, Italy.
Background:
Driving pressure (ΔP) represents tidal volume normalised to respiratory system compliance (CRS) and is a novel parameter to target ventilator settings. We conducted a study to determine whether CRS and ΔP reflect aerated lung volume and dynamic strain during general anaesthesia.
Methods:
Twenty non-obese patients undergoing open abdominal surgery received three PEEP levels (2, 7, or 12 cm H2O) in random order with constant tidal volume ventilation. Respiratory mechanics, lung volumes, and alveolar recruitment were measured to assess end-expiratory aerated volume, which was compared with the patient's individual predicted functional residual capacity in supine position (FRCp).
Results:
CRS was linearly related to aerated volume and ΔP to dynamic strain at PEEP of 2 cm H2O (intraoperative FRC) (r=0.72 and r=0.73, both P<0.001). These relationships were maintained with higher PEEP only when aerated volume did not overcome FRCp (r=0.73, P<0.001; r=0.54, P=0.004), with 100 ml lung volume increases accompanied by 1.8 ml cm H2O-1 (95% confidence interval [1.1-2.5]) increases in CRS. When aerated volume was greater or equal to FRCp (35% of patients at PEEP 2 cm H2O, 55% at PEEP 7 cm H2O, and 75% at PEEP 12 cm H2O), CRS and ΔP were independent from aerated volume and dynamic strain, with CRS weakly but significantly inversely related to alveolar dead space fraction (r=-0.47, P=0.001). PEEP-induced alveolar recruitment yielded higher CRS and reduced ΔP only at aerated volumes below FRCp (P=0.015 and 0.008, respectively).
Conclusions:
During general anaesthesia, respiratory system compliance and driving pressure reflect aerated lung volume and dynamic strain, respectively, only if aerated volume does not exceed functional residual capacity in supine position, which is a frequent event when PEEP is used in this setting.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Lung Capacity
Anatomy of Respiratory System II: Lower Respiratory Tract
The Larynx
It is located between the pharynx and the trachea, acts as a passageway for air, and hosts several critical structures, such as the epiglottis, vocal cords, and glottis. The epiglottis acts as a gateway, guiding food to the...
The Respiratory System