Dosimetric impact of interfractional organs at risk variation during high-dose rate interstitial brachytherapy for
Peter G Hawkins1, Ming Tang2, Karen A Vineberg1
1Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA.
Abstract:
We sought to develop a framework for the identification and management of patients at risk for organs at risk (OARs) overdosing due to interfractional anatomic variation during high-dose rate interstitial brachytherapy for gynecologic malignancies. We analyzed 40 high-dose rate interstitial brachytherapy fractions from 10 patients. Planned OAR doses were compared to delivered doses, which were calculated from computed tomography scans obtained prior to each treatment fraction. Doses were converted to equivalent doses in 2 Gy fractions (EQD2) and doses to the most exposed 2 cm3 (D2cc) were reviewed. Patients were risk-stratified by identifying dose thresholds corresponding to a 10% or lower risk of receiving an OAR dose exceeding the corresponding planning constraint. For each OAR, 30% to 62.5% of patients received total doses greater than planned, although the magnitude of these differences was <4 Gy in over 75% of cases. Using EMBRACE II guidelines, one patient who had met the planning constraint for bladder and one for small bowel were found to have received doses exceeding the recommended limits. We next calculated thresholds for estimating the risk of OAR overdosing in individual patients and developed a framework based on these thresholds to direct time- and resource-intensive imaging and replanning efforts toward patients who are most likely to derive benefit. In summary, differential OAR dosing due to interfractional anatomic variation is common but likely rarely clinically meaningful. The proposed framework could decrease toxicity and maximize clinical efficiency.
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Factors Affecting Drug Distribution: Organ Perfusion Rate
Perfusion rate-limited distribution relies on the...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...