Mesh OR Patch for Hernia on Epigastric and Umbilical Sites (MORPHEUS-Trial): The Complete Two-year Follow-up
Jeroen E H Ponten1, Wouter K G Leclercq2, Tanja Lettinga3
1Department of Surgery, Catharina Ziekenhuis Eindhoven, Eindhoven, The Netherlands.
Objective:
The objective of this trial was to identify a superior method for umbilical and epigastric hernia repair in terms of complications. Complications such as an extended operation duration, additional use of painkillers, reoperation, infection, seroma, extended wound care, extended hospitalization, and early recurrence were reported according to the Clavien-Dindo grading system.
Summary Background Data:
Over the years mesh repair is proven the gold standard for umbilical and epigastric hernias. The question remains, which mesh should be used?
Methods:
In this randomized controlled, multicenter trial, all patients ≥ 18 years with a single, symptomatic, and primary small umbilical or epigastric hernia qualified for inclusion. Flat preperitoneal polypropylene mesh repair was compared with patch repair (PROCEED Ventral Patch) (PVP).
Results:
A total of 352 patients were randomized; 348 patients received the intervention (n = 177 PVP vs n = 171 mesh). One out of 4 suffered from any kind of complication within 2 years postoperative (27.6%). A significant difference in complications was seen, in favor of polypropylene mesh repair (P = 0.044, 22.1% mesh vs 32.5% PVP). Reoperation was performed in 19 PVP operated patients (10.7%) versus 7 patients with polypropylene mesh repair (4.0%, P = 0.021).No significant differences were seen in recurrences (n = 13, 8.4% PVP vs n = 6, 4.1% mesh, P = 0.127).
Conclusions:
In small epigastric and small umbilical hernia repair a flat polypropylene mesh repair was associated with a lower complication rate than PVP repair. No differences in recurrence rates were seen. Combining all complications, the preperitoneal positioned flat polypropylene mesh performed better.
Related Concept Videos
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Ligand Binding Sites
Clinical Trials: Overview
Trial and Error and Algorithm