Related Experiment Video
Updated: Feb 3, 2026

05:03
Using Alizarin Red Staining to Detect Chemically Induced Bone Loss in Zebrafish Larvae
Published on: December 28, 2021
6.0K
Corrigendum: Ulinastatin Inhibits Osteoclastogenesis and Suppresses Ovariectomy-Induced Bone Loss by Downregulating
Jun-Ming Huang1, Ran-Yue Ren1, Yuan Bao1
1Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Frontiers in Pharmacology
|October 23, 2018
Abstract:
[This corrects the article DOI: 10.3389/fphar.2018.01016.].
More Related Videos
Related Concept Videos
Receptor Downregulation in MVBs
2.8K
Multivesicular bodies (MVBs) are mature endosomes that sort ubiquitinated proteins and then fuse with lysosomes to degrade the sorted proteins. Epidermal growth factor (EGF) and its receptor (EGFR) form a complex that can be internalized through endocytosis, sorted into an MVB, and later degraded.
The EGFR can initiate signaling pathways that lead to cell proliferation, migration, and differentiation. Overexpression of EGFR stimulates cells to proliferate. Excessive EGFR...
The EGFR can initiate signaling pathways that lead to cell proliferation, migration, and differentiation. Overexpression of EGFR stimulates cells to proliferate. Excessive EGFR...
2.8K
Feedback Inhibition
57.1K
Biochemical reactions are occurring constantly in cells, converting starting substances to different products, usually with the help of enzymes that speed the reactions. Without enzymes, it would take far too long for most reactions to occur to be useful to the cell!
57.1K
Line Loss
543
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
543
Reducing Line Loss
390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Major Losses in Pipes
2.0K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K

