Related Experiment Video
Updated: Feb 3, 2026

Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
On the relevance of denoising and artefact reduction in 3D segmentation and classification within complex computed
Andre Mouton1, Toby P Breckon2
1School of Engineering, Cranfield University, Bedfordshire, UK.
Abstract:
We evaluate the impact of denoising and Metal Artefact Reduction (MAR) on 3D object segmentation and classification in low-resolution, cluttered dual-energy Computed Tomography (CT). To this end, we present a novel 3D materials-based segmentation technique based on the Dual-Energy Index (DEI) to automatically generate subvolumes for classification. Subvolume classification is performed using an extension of Extremely Randomised Clustering (ERC) forest codebooks, constructed using dense feature-point sampling and multiscale Density Histogram (DH) descriptors. Within this experimental framework, we evaluate the impact on classification accuracy and computational expense of pre-processing by intensity thresholding, Non-Local Means (NLM) filtering, Linear Interpolation-based MAR (LIMar) and Distance-Driven MAR (DDMar) in the domain of 3D baggage security screening. We demonstrate that basic NLM filtering, although removing fewer artefacts, produces state-of-the-art classification results comparable to the more complex DDMar but at a significant reduction in computational cost - bringing into question the importance (in terms of automated CT analysis) of computationally expensive artefact reduction techniques. Overall, it was found that the use of MAR pre-processing approaches produced only a marginal improvement in classification performance (< 1%) at considerable additional computational cost (> 10×) when compared to NLM pre-processing.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Oxidation-Reduction Reactions
Force Classification
Contact and non-contact forces are two of the most widely used categories of forces. As the name suggests, contact forces require physical contact between two objects to act upon each other. Examples of contact forces include frictional,...
Classification of Neurotransmitters
Classification of Leukocytes
Neutrophils are the most abundant type of granular leukocytes, comprising 50-70% of all leukocytes. They feature small, evenly distributed granules and a...