Sensitive determination of perfluoroalkane sulfonamides in water and urine samples by multiple monolithic fiber

Yanmei Huang1, Min Lu1, Haiyan Li1

  • 1State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005, China; Key Laboratory of the Ministry of Education for Coastal and Wetland Ecosystems, College of the Environment and Ecology, Xiamen University, Xiamen 361005, China.

Talanta
|October 24, 2018
PubMed

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.5K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.4K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Urine Studies II: Urine Culture and Sensitivity Test01:26

Urine Studies II: Urine Culture and Sensitivity Test

A urine culture and sensitivity test is a diagnostic procedure used to identify urinary tract bacterial infections and determine the most effective antibiotics for treatment. This test is generally preferred when a patient shows manifestations of a urinary tract infection, such as frequent or painful urination, cloudy or foul-smelling urine, or lower abdominal pain.Purpose of the TestThe primary goals of a urine culture and sensitivity test are to:Determine the specific bacteria causing the...
1.1K
Molecular Comparison of Gases, Liquids, and Solids02:26

Molecular Comparison of Gases, Liquids, and Solids

Particles in a solid are tightly packed together (fixed shape) and often arranged in a regular pattern; in a liquid, they are close together with no regular arrangement (no fixed shape); in a gas, they are far apart with no regular arrangement (no fixed shape). Particles in a solid vibrate about fixed positions (cannot flow) and do not generally move in relation to one another; in a liquid, they move past each other (can flow) but remain in essentially constant contact; in a gas, they move...
55.1K
Speed of Sound in Solids and Liquids00:51

Speed of Sound in Solids and Liquids

Most solids and liquids are incompressible—their densities remain constant throughout. In the presence of an external force, the molecules tend to restore to their original positions, which is only possible because the constituents interact. The interactions help the constituents pass on information about external disturbances, like sound waves. Therefore, sound waves travel faster through these media. Compared to solids, the constituents in a liquid are less tightly bound. Thus, sound...
3.9K