Development and validation of a pneumatic model for the reversed-flow differential flow modulator for comprehensive
Matthew Giardina1, James D McCurry1, Pascal Cardinael2
1Gas Phase Separations Division, Agilent Technologies, 2850 Centerville Rd, Wilmington, DE 19808, USA.
Abstract:
The development of the reversed fill/flush modulator represents a significant advancement in flow-modulated, comprehensive two-dimensional gas chromatography (GC × GC). Compared to the forward flush/fill modulator, the reversed-flow modulator is less susceptible to baseline anomalies and peak tailing as a result of modulator channel overfilling or insufficient purging of high concentration analytes. Flow reversal requires the addition of a bleed capillary not present in the forward-flow modulator. Selecting the appropriate restriction of the bleed capillary is critical. If the bleed capillary is too restrictive, eluate from the first-dimension column can split between the modulator channel and second-dimension column, which also results in baseline artifacts. To gain a better understanding of the reversed-flow modulator, a comprehensive pneumatic model was developed. The model was validated by comparing calculated and measured hold-up times. The errors in calculated hold-up times were less than 1% of the measured values. The model can be used to predict first-dimension eluate splitting and determine the optimal bleed capillary dimensions to prevent its occurrence. Calculation of the modulator hold-up time can be used to determine the maximum collection time to ensure comprehensive analysis and optimal flush times for partial fill operation.
More Related Videos
09:58Investigating the Three-dimensional Flow Separation Induced by a Model Vocal Fold Polyp
Published on: February 3, 2014
09:32Light-mediated Reversible Modulation of the Mitogen-activated Protein Kinase Pathway during Cell Differentiation and Xenopus Embryonic Development
Published on: June 15, 2017
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gene Flow
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...