Related Experiment Video
Updated: Feb 3, 2026

Lower Limb Biomechanical Analysis of Healthy Participants
Published on: April 15, 2020
Biomechanical Strength of Scaphoid Partial Unions
Adam C Brekke1, Mark C Snoddy1, Donald H Lee1
1Department of Orthopaedics and Rehabilitation, Vanderbilt University Medical Center, Nashville, Tennessee.
Abstract:
Background It remains unknown how much force a partially united scaphoid can sustain without refracturing. This is critical in determining when to discontinue immobilization in active individuals. Purpose The purpose of this study was to test the biomechanical strength of simulated partially united scaphoids. We hypothesized that no difference would exist in load-to-failure or failure mechanism in scaphoids with 50% or more bone at the waist versus intact scaphoids. Materials and Methods Forty-one cadaver scaphoids were divided into four groups, three experimental osteotomy groups (25, 50, and 75% of the scaphoid waist) and one control group. Each was subjected to a physiologic cantilever force of 80 to 120 N for 4,000 cycles, followed by load to failure. Permanent deformation during physiologic testing and stiffness, max force, work-to-failure, and failure mechanism during load to failure were recorded. Results All scaphoids survived subfailure conditioning with no significant difference in permanent deformation. Intact scaphoids endured an average maximum load to failure of 334 versus 321, 297, and 342 N for 25, 50, and 75% groups, respectively, with no significant variance. There were no significant differences in stiffness or work to failure between intact, 25, 50, and 75% groups. One specimen from each osteotomy group failed by fracturing through the osteotomy; all others failed near the distal pole loading site. Conclusion All groups behaved similarly under physiologic and load-to-failure testing, suggesting that inherent stability is maintained with at least 25% of the scaphoid waist intact. Clinical Relevance The data provide valuable information regarding partial scaphoid union and supports mobilization once 25% union is achieved.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Partial Fractions
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...

