Related Experiment Video
Updated: Feb 3, 2026

How to Ignite an Atmospheric Pressure Microwave Plasma Torch without Any Additional Igniters
Published on: April 16, 2015
Replacing the Argon ICP: Nitrogen Microwave Inductively Coupled Atmospheric-Pressure Plasma (MICAP) for Mass
Matthias Schild1, Alexander Gundlach-Graham1, Ashok Menon2
1Department of Chemistry and Applied Biosciences , ETH Zurich , Vladimir-Prelog-Weg 1 , 8093 Zurich , Switzerland.
Abstract:
We combine a recently developed high-power, nitrogen-sustained microwave plasma source-the Microwave Inductively Coupled Atmospheric-Pressure Plasma (MICAP)-with time-of-flight mass spectrometry (TOFMS) and provide the first characterization of this elemental mass spectrometry configuration. Motivations for assessment of this ionization source are scientific and budgetary: unlike the argon-sustained Inductively Coupled Plasma (ICP), the MICAP is sustained with nitrogen, which eliminates high operating costs associated with argon-gas consumption. Additionally, use of a commercial grade magnetron for microwave generation simplifies plasma-powering electronics. In this study, we directly compare MICAP-TOFMS performance with that of an argon-ICP as the atomic ionization source on the same TOFMS instrument. Initial results with the MICAP source demonstrate limits of detection and sensitivities that are, for most elements, on par with those of the ICP-TOFMS. The N2-MICAP source provides a much "cleaner" background spectrum than the ICP; absence of argon-based interferences greatly simplifies analysis of isotopes such as 40Ca, 56Fe, and 75As, which typically suffer from spectral interferences in ICP-MS. The major plasma species measured from the N2-MICAP source include NO+, N2+, N+, N3+, O2+, N4+, and H2O+; we observed no plasma-background species above mass-to-charge 60. Absence of troublesome argon-based spectral interferences is a compelling advantage of the MICAP source. For example, with MICAP-TOFMS, the limit of detection for arsenic is less than 100 ng L-1 even in a 1% NaCl solution; with ICP-MS, 35Cl40Ar+ interferes with 75As+ and arsenic analysis is difficult-to-impossible in chlorine-containing matrices.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...