Related Experiment Video
Updated: Feb 3, 2026

Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
A large aperture row column addressed probe for in vivo 4D ultrafast doppler ultrasound imaging
J Sauvage1, M Flesch1,2, G Férin2
1Institut Langevin, ESPCI ParisTech, PSL Research University, CNRS UMR7587, INSERM U979, 17 rue Moreau, 75012 Paris, France.
Abstract:
Four-dimensional (4D) Ultrafast ultrasound imaging was recently proposed to image and quantify blood flow with high sensitivity in 3D as well as anatomical, mechanical or functional information. In 4D Ultrafast imaging, coherent compounding of tilted planes waves emitted by a 2D matrix array were used to image the medium at high volume rate. 4D ultrafast imaging, however, requires a high channel count (>1000) to drive those probes. Alternative approaches have been proposed and investigated to efficiently reduce the density of elements, such as sparse or under-sampled arrays while maintaining a decent image quality and high volume rate. The row-columns configuration presents the advantage of keeping a large active surface with a low amount of elements and a simple geometry. In this study, we investigate the row and column addressed (RCA) approach with the orthogonal plane wave (OPW) compounding strategy using real hardware limitations. We designed and built a large 7 MHz 128 + 128 probe dedicated to vascular imaging and connected to a 256-channel scanner to implement the OPW imaging scheme. Using this strategy, we demonstrate that 4D ultrafast Power Doppler imaging of a large volume of [Formula: see text] up to [Formula: see text] depth, both in vitro on flow phantoms and in vivo on the carotid artery of a healthy volunteer at a volume rate of 834 Hz.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - I
Doppler Effect - II
Strategies for Assessing and Addressing Confounding
Confounding can be addressed at both the design phase of a study and through analytical methods after data...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...