Related Experiment Video
Updated: Feb 3, 2026

Determining The Electromyographic Fatigue Threshold Following a Single Visit Exercise Test
Published on: July 27, 2015
Non-exhaustive double effort test is reliable and estimates the first ventilatory threshold intensity in running
Lucas Dantas Maia Forte1, Fúlvia Barros Manchado-Gobatto1, Roberta Cunha Matheus Rodrigues2
1School of Applied Science, University of Campinas, São Paulo 13484-350, Brazil.
Purpose:
The present study aimed to investigate the reliability of the non-exhaustive double effort (NEDE) test in running exercise and its associations with the ventilatory thresholds (VT1 and VT2) and the maximal lactate steady state (MLSS).
Methods:
Ten healthy male adults (age: 23 ± 4 years, height: 176.6 ± 6.4 cm, body mass: 76.6 ± 10.7 kg) performed 4 procedures: (1) a ramp test for VT1 and VT2 determinations measured by ratio of expired ventilation to O2 uptake (VE/VO2) and expired ventilation to CO2 output (VE/VCO2) equivalents, respectively; (2) the NEDE test measured by blood lactate concentration (NEDELAC) and heart rate responses (NEDEHR); (3) a retest of NEDE for reliability analysis; and (4) continuous efforts to determine the MLSS intensity. The NEDE test consisted of 4 sessions at different running intensities. Each session was characterized by double efforts at the same running velocity (E1 and E2, 180 s), separated by a passive recovery period (90 s rest). LAC and HR values after E1 and E2 (in 4 sessions) were used to estimate the intensity equivalent to "null delta" by linear fit. This parameter represents, theoretically, the intensity equivalent to maximal aerobic capacity.
Results:
The intraclass correlation coefficient indicated significant reliability for NEDELAC (0.93) and NEDEHR (0.79) (both p < 0.05). There were significant correlations, no differences, and strong agreement with the intensities predicted by NEDELAC (10.1 ± 1.9 km/h) and NEDEHR (9.8 ± 2.0 km/h) to VT1 (10.2 ± 1.1 km/h). In addition, despite significantly lower MLSS intensity (12.2 ± 1.2 km/h), NEDELAC and NEDEHR intensities were highly correlated with this parameter (0.90 and 0.88, respectively).
Conclusion:
The NEDE test applied to running exercise is reliable and estimates the VT1 intensity. Additionally, NEDE intensities were lower but still correlated with VT2 and MLSS.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
06:28A Chronic High-Intensity Interval Training and Diet-Induced Obesity Model to Maximize Exercise Effort and Induce Physiologic Changes in Rats
Published on: April 28, 2023
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Reliability and Validity
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
Wald-Wolfowitz Runs Test I
The test works...
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Sound Intensity