Related Experiment Video
Updated: Feb 3, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
A novel dynamic arc treatment planning solution to reduce dose to small bowel in preoperative radiotherapy for rectal
Victoria S Brennan1, Brendan Curran1, Christina Skourou1
1St Luke's Radiation Oncology Network, Beaumont Hospital, Dublin D06 HH36, Ireland.
Abstract:
Preoperative radiotherapy or combined chemoradiotherapy for locally advanced rectal cancer (LARC) can cause acute and late gastrointestinal (GI) side-effects. There is thought to be a dose-volume relationship between small bowel irradiation and the development of these effects. A planning study was undertaken to compare small bowel sparing for a range of 3D conformal and dynamic arc planning solutions. A planning study was carried out for 20 LARC patients. Organs at risk (OAR) contoured included bowel loops and peritoneal space (PS). For each of the 20 patients, 5 plans were created: (1) standard 3D conformal plan; (2) standard dual dynamic arc plan; (3) dual dynamic arc plan with 90° avoidance sector through the anterior portion of the patient; (4) dual dynamic arc plan with an anterior avoidance structure in the optimizer; (5) dual dynamic arc plan with both an anterior avoidance structure and an avoidance sector. The prescription was 50.4 Gy in 28 fractions to the planning target volume (PTV). Five Dose Volume Levels (DVLs; V15 Gy, V20 Gy, V25 Gy, V35 Gy, V40 Gy, and V50.4 Gy) for bowel and PS were selected. The DVLs were compared between the plans using Friedman Tests and Wilcoxon Signed Rank Tests. Comparison of the 5 plans revealed that a dual dynamic arc plan containing both an anterior avoidance sector and structure significantly improved the dose to the bowel compared to a standard 3D conformal plan and to a standard dual dynamic arc plan. This improvement was achieved while maintaining PTV coverage. This novel dual dynamic arc planning technique that uses both an avoidance sector and structure reduces the dose to the bowel and PS, which may lead to a reduction in GI toxicity.
Related Concept Videos
Arc Length of a Curve
Arc Length Function
Treatment Resistant Cancers
Arc Length of a Curve: Problem Solving
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Solution Equilibrium and Saturation

