Related Experiment Video
Updated: Feb 3, 2026

Preparation and Using Phantom Lesions to Practice Fine Needle Aspiration Biopsies
Published on: September 29, 2009
A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle
Priscilla A van Riet1, Alberto Larghi2, Fabia Attili2
1Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands.
Background And Aims:
Several studies have compared EUS-guided FNA with fine-needle biopsy (FNB), but none have proven superiority. We performed a multicenter randomized controlled trial to compare the performance of a commonly used 25-gauge FNA needle with a newly designed 20-gauge FNB needle.
Methods:
Consecutive patients with a solid lesion were randomized in this international multicenter study between a 25-gauge FNA (EchoTip Ultra) or a 20-gauge FNB needle (ProCore). The primary endpoint was diagnostic accuracy for malignancy and the Bethesda classification (non-diagnostic, benign, atypical, malignant). Technical success, safety, and sample quality were also assessed. Multivariable and supplementary analyses were performed to adjust for confounders.
Results:
A total of 608 patients were allocated to FNA (n = 306) or FNB (n = 302); 312 pancreatic lesions (51%), 147 lymph nodes (24%), and 149 other lesions (25%). Technical success rate was 100% for the 25-gauge FNA and 99% for the 20-gauge FNB needle (P = .043), with no differences in adverse events. The 20-gauge FNB needle outperformed 25-gauge FNA in terms of histologic yield (77% vs 44%, P < .001), accuracy for malignancy (87% vs 78%, P = .002) and Bethesda classification (82% vs 72%, P = .002). This was robust when corrected for indication, lesion size, number of passes, and presence of an on-site pathologist (odds ratio, 3.53; 95% confidence interval, 1.55-8.56; P = .004), and did not differ among centers (P = .836).
Conclusion:
The 20-gauge FNB needle outperformed the 25-gauge FNA needle in terms of histologic yield and diagnostic accuracy. This benefit was irrespective of the indication and was consistent among participating centers, supporting the general applicability of our findings. (Clinical trial registration number: NCT02167074.).
Related Concept Videos
Pressure Gauges
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...

