Related Experiment Video
Updated: Feb 3, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Limb lengthening and deformity correction with externally controlled motorized intramedullary nails: evaluation of 50
Joachim Horn1, Ivan Hvid1, Stefan Huhnstock1
1a Section of Children's Orthopaedics and Reconstructive Surgery, Division of Orthopaedic Surgery , Oslo University Hospital ;
Abstract:
Background and purpose - Limb lengthening with an intramedullary motorized nail is a relatively new method. We investigated if lengthening nails are reliable constructs for limb lengthening and deformity correction in the femur and the tibia. Patients and methods - 50 lengthenings (34 Precice and 16 Fitbone devices) in 47 patients (mean age 23 years [11-61]) with ≥12 months follow-up are included in this study. 30 lengthenings were done due to congenital and 20 because of posttraumatic deformity (21 antegrade femora, 23 retrograde femora, 6 tibiae). Initial deformities included a mean shortening of 42 mm (25-90). In 15 patients, simultaneous axial correction was done using the retrograde nailing technique. Results - The planned amount of lengthening was achieved in all but 2 patients. 5 patients who underwent simultaneous axial correction showed minor residual deformity; unintentionally induced minor deformities were found in the frontal and sagittal plane. The consolidation index was 1.2 months/cm (0.6-2.5) in the femur and 2.5 months/cm (1.6-4.0) in the tibia. 2 femoral fractures occurred in retrograde femoral lengthenings after consolidation due to substantial trauma. There were 8 complications, all of which were correctable by surgery, with no permanent sequelae. Interpretation - Controlled acute axial correction of angular deformities and limb lengthening can be achieved by a motorized intramedullary nail. A thorough preoperative planning and intraoperative control of alignment are required to avoid residual and unintentionally induced deformity. In the femur relatively fast consolidation could be observed, whereas healing was slower in the tibia.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
09:42Author Spotlight: Using Motor Imagery Brain-Computer Interface to Improve Motor and Cognitive Function in Stroke Patients
Published on: September 1, 2023
Related Concept Videos
Hierarchy of Motor Control
Distance Corrections
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Plastic Deformations
Plastic Deformations
Power Factor Correction