Head positioning in a cone beam computed tomography unit and the effect on accuracy of the three-dimensional surface
Harry C Stamatakis1, Ralph Steegman1, Joost Dusseldorp1
1Department of Orthodontics, University of Groningen, University Medical Centre Groningen, Groningen, the Netherlands.
Abstract:
Head position during cone beam computed tomography (CBCT) examination can easily deviate from the ideal, which may affect the accuracy of the segmented three-dimensional (3D) model. The aim of this study was to determine the effect of head positioning on the accuracy of the 3D model. A human dry skull was positioned at predetermined orientations in a CBCT scanner and scanned in multiple orientations and voxel sizes. The resulting 3D surface models were superimposed over those derived from the reproducible centered positioned skull with 0° inclination. Color mapping and analysis of the differences expressed by the root mean square error (RMSE) were performed. The RMSE for each orientation using the 0.3 mm voxel ranged from 0.31 to 0.87 mm for the whole maxillofacial region, from 0.44 to 0.91 mm in the maxilla, and from 0.31 to 0.72 mm in the mandible. For the 0.4 mm voxel, the RMSE ranged from 0.47 to 0.86 mm for the whole maxillofacial region, from 0.60 to 0.96 mm in the maxilla, and from 0.56 to 0.86 mm in the mandible. The maxilla showed a slightly higher deviation than the mandible in both voxel groups. It can be concluded that the head position affects the accuracy of the segmented 3D model, but the inaccuracy does not exceed clinically relevant levels.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...