Variability in Repeated Blood Pressure Measurements as a Marker of Frailty
1Prof Jean Woo, Department of Medicine and Therapeutics, Prince of Wales Hospital, Shatin, N.T., Hong Kong, Tel: 852-3505-3493, Fax: 852-2637-3852
Objectives:
Variation in repeated blood pressure measurements may represent a decline in homeostatic mechanisms in blood pressure regulation in response to various internal or external stressors, indicating a frail state. We tested this hypothesis by examining the association between variability in repeated blood pressure measurements (BPV) and frailty status, adjusting for other confounding factors.
Design:
A longitudinal cohort study.
Setting:
Community centres in all three regions of Hong Kong.
Participants:
1156 community-living older adults aged 60 years and over participated in a community geriatric screening program with blood pressure measurements three times a week over one year. Participants were divided into three groups based on variability of repeated blood pressure measurements (low, medium, high) using machine learning methods.
Measurements:
Frailty status was assessed using the FRAIL scale. Logistic regression was used to examine cross sectional association between frailty status and BPV adjusting for confounding factors, and also frailty transition with BPV.
Results:
In multi-variate models adjusting for co-variates, high BPV was associated with frailty (OR 1.57; 95% CI 1.05-2.37) among all participants; however, this was only significant in women in subgroup analysis. Similar findings were observed when transition to a more frail state was examined over a twelve month period.
Conclusions:
The findings of this study support the concept of physiological dysregulation underlying the frail state, and that BPV calculated using machine learning methods may be used as a biomarker of such dysregulation.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...