Purpose:
To evaluate the repeatability and between-machine/operator reproducibility of optical coherence tomography (RTVue-XR) for mapping corneal epithelial thickness (ET) and corneal thickness (CT) over a 9-mm zone.
Methods:
In 5 groups of eyes (normal, contact lens, dry eye, post-LASIK/PRK, and keratoconus), corneal ET and CT were evaluated in 25 areas in the following 4 regions: 1) 1 central zone within 0 to 2.0 mm diameter, 2) 8 paracentral zones from 2.0 to 5.0 mm diameter, 3) 8 midperipheral zones from 5.0 to 7.0 mm diameter, and 4) 8 peripheral zones from 7.0 to 9.0 mm diameter. Three devices with designated operators were used to obtain 3 scans per device for each eye. The repeatability, reproducibility, and coefficient of variation were calculated.
Results:
For all areas up to 9 mm diameter, in normal eyes, contact lens eyes, dry eyes, post- LASIK/PRK eyes, and keratoconic eyes, repeatability and reproducibility ranged from 0.7 to 1.5, 1.0 to 2.6, 0.9 to 2.0, 0.7 to 2.5, and 1.1 to 2.3 μm for ET and 1.5 to 8.3, 2.3 to 12.1, 1.7 to 14.2, 1.4 to 13.7, and 6.9 to 18.9 μm for CT, respectively. The ranges of coefficient of variation values were 1.2% to 3.0%, 1.9% to 5.5%, 1.8% to 4.3%, 1.3% to 5.2%, and 2.2% to 4.5% for ET and 0.3% to 1.2%, 0.4% to 1.8%, 0.4% to 2.1%, 0.3% to 2.0%, and 1.2% to 3.0% for CT, respectively.
Conclusions:
Optical coherence tomography produced excellent repeatability and reproducibility for corneal ET and CT measurements up to a 9-mm zone in normal eyes and eyes with different corneal conditions. The CT measurements in keratoconic eyes were more variable than those in eyes with other corneal conditions.
Related Concept Videos
Hybrid Zones
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Transition Zone
Self-Evaluation: Self-Enhancement and Self-Verification
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...