An integrated impedance biosensor platform for detection of pathogens in poultry products

Jiayu Liu1, Ibrahem Jasim1, Amjed Abdullah1

  • 1University of Missouri - Columbia, Electrical and Computer Engineering, Columbia, 65211, USA.

Scientific Reports
|November 2, 2018
PubMed

Related Concept Videos

Impedance Combination01:21

Impedance Combination

Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage...
753
Impedances and Admittance01:23

Impedances and Admittance

In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
1.9K
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
445
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
531
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
454
Integration by Parts: Indefinite Integrals01:26

Integration by Parts: Indefinite Integrals

Integration by parts is a fundamental technique in calculus for evaluating integrals involving the product of two functions. It is particularly useful when direct integration is not feasible. The method is based on the product rule for differentiation, which states that the derivative of a product equals the derivative of the first function times the second, plus the first function times the derivative of the second. By integrating this identity and rearranging terms, the integration by parts...
171