Synthetic transmit aperture beamforming for sound velocity estimation using channel-domain differential phase

Che-Chou Shen1, Sheng-Hsuan Hsiao1, Yen-Chung Lin2

  • 1Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.

Ultrasonics
|November 3, 2018
PubMed

Related Concept Videos

Electrochemical Gradient and Channel Proteins: An Overview01:21

Electrochemical Gradient and Channel Proteins: An Overview

An electrochemical gradient is a fundamental concept in biology and chemistry. It regulates the movement of ions across cell membranes. This movement is influenced by two factors:
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell.  This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
4.7K
What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
127.8K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
454
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
420
Sexually Transmitted Infections01:26

Sexually Transmitted Infections

Sexually transmitted infections (STIs) are diseases transmitted primarily through unsafe sexual interactions. Bacteria, viruses, or parasites cause them and can result in severe health complications if untreated.ChlamydiaThe bacterium Chlamydia trachomatis is responsible for the disease Chlamydia, the most common STI in the United States. This peculiar pathogen requires human cells to reproduce, residing intracellularly. The initial infection often goes unnoticed because it typically does not...
1.1K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
13.5K