Correction of magnetic field inhomogeneity effects for fast quantitative susceptibility mapping
Giang-Chau Ngo1, Berkin Bilgic2,3, Borjan A Gagoski4
1Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois.
Purpose:
Quantitative susceptibility mapping (QSM) provides information about tissue composition and organization. However, current acquisition methods can be quite time consuming, limiting the use of QSM in studies and in monitoring dynamic events. In this work, time efficient spiral acquisitions are combined with a model-based image reconstruction approach. Magnetic field inhomogeneity artifacts are corrected to obtain full brain susceptibility maps.
Methods:
Magnetic field maps, capturing the magnetic field inhomogeneity distribution due to non-tissue sources (background field), were estimated from a calibration scan. Tissue phase information present in the background field maps was identified using variable spherical mean value filtering and removed from the estimated field maps. The resulting background field maps were then used in the image reconstruction to correct the magnetic field inhomogeneity artifacts. Images were acquired on a 3 T system with a 3D spiral-in acquisition based on a rotated stack of spirals. For comparison, standard gradient echo images were also acquired. Susceptibility maps were obtained for both acquisitions using a dipole inversion algorithm based on a compressed sensing compensated formulation with wavelet and total variation penalties.
Results:
Susceptibility maps obtained with the spiral acquisition and the model-based reconstruction agree with the ones obtained with the spin-warp gradient echo acquisition. Using the 3D spiral acquisition, full brain susceptibility maps at the resolution of 1 mm isotropic are obtained in 23 s CONCLUSIONS: Image distortions and blurring due to magnetic field inhomogeneity are removed while maintaining tissue magnetic susceptibility information, resulting in QSM maps in much shorter acquisition time.
More Related Videos
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...
Magnetic Field Of A Current Loop