Related Experiment Video
Updated: Feb 3, 2026

Combustion Characterization and Model Fuel Development for Micro-tubular Flame-assisted Fuel Cells
Published on: October 2, 2016
Modelling of vapour intrusion into a building impacted by a fuel spill in Antarctica
R S McWatters1, R K Rowe2, D Wilkins1
1Antarctic Conservation and Management, Australian Antarctic Division, Kingston, Tasmania, Australia.
Abstract:
A new vapour intrusion contaminant transport model was designed specifically to allow an assessment of the impact of a hydrocarbon fuel spill on air quality in cold region buildings. The model is applied to a recent situation in Antarctica, where a diesel spill impacted the construction of a new building. For the first time, this model allows consideration of the diffusive resistance of different vapour barrier to the transport of hydrocarbons into the building and an assessment of the effectiveness of different products. Site specific indoor air criteria are derived. Five scenarios are modelled at field temperatures: (1) build on current contaminated site; (2) excavate contaminated soil, backfill with clean soil and assess impact of residual contamination; (3) excavate and backfill with remediated (biopile) soil; (4) backfill with remediated soil and assess impact of residual contamination; (5) backfill with remediated soil and assess impact of a potential future fuel spill. Two different vapour barriers, a co-extruded ethylene vinyl alcohol (EVOH) geomembrane (VB1) and a linear low-density (LLDPE) geomembrane (VB2), are investigated for each scenario and compared to a base case with no vapour barrier, providing quantifiable evidence of the benefit of installing an engineered vapour barrier Contaminant concentrations were below regulatory limits for Scenarios (2-5) with VB1 and air exchange in the building. For all scenarios, the EVOH geomembrane (VB1) was consistently superior at reducing vapour transport into the building indoor air space over the LLDPE geomembrane (VB2) and no vapour barrier. The risk mitigation measures developed for this contaminated Antarctic site may be relevant for other buildings in cold regions.
Related Concept Videos
Batteries and Fuel Cells
Impact of Groups on Groups
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...
Types of Building Stone
Igneous rocks are formed from the solidification of magma or lava. An example is granite, known for its durability and resistance to weathering, making it ideal for parts of...
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...