Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Minimally Invasive Ozaki Procedure in Aortic Valve Disease: The Preliminary Results
Dinh H Nguyen, Anh T Vo1, Khoi M Le1
1Department of Cardiovascular Surgery, University Medical Center, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Objective:
The Ozaki procedure for aortic valve reconstruction was reported in 2014 with low mortality, a highly reproducible rate and a good midterm result. However, the procedure still requires conventional sternotomy to be accomplished. The aim of the study was to start an initial evaluation for the feasibility of the minimally invasive approach in combination with the Ozaki technique.
Methods:
From January 06, 2017, to January 12, 2017, nine patients with severe aortic valve diseases underwent minimally invasive Ozaki procedure through an upper ministernotomy. The pericardium was harvested endoscopically using three trocars in different intercostal spaces. Then, a ministernotomy was performed and the Ozaki procedure was accomplished in a similar manner to the conventional technique. We analyzed the in-hospital mortality and complications of this group.
Results:
The mean age was 47.4 years and 55.6% patients were female. The predominant pathology was chronic rheumatic valve disease (66.7%) and other patients were diagnosed with a bicuspid aortic valve. The mean aortic cross-clamp time was 106.8 minutes, the mean cardiopulmonary bypass time was 153.6 minutes, the mean ventilation time was 8.4 hours, and the mean intensive care unit time was 1.6 days. No mortality was recorded in our series, no conversion to full sternotomy was required, one patient experienced right hemothorax requiring drainage, and one patient required valve replacement. Intraoperative transesophageal echocardiography and predischarge transthoracic echocardiography showed five competent valves and three valves with trivial regurgitation, and no stenosis was detected.
Conclusions:
Ministernotomy combined with Ozaki procedure might be feasible, as well as an alternative to conventional sternotomy. This approach is associated with low mortality and morbidity and may be beneficial in younger populations.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Blind Procedures
Mitral Valve Prolapse II: Assessment and Management
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...