Determining 3D Flow Fields via Multi-camera Light Field Imaging
Published on: March 6, 2013
Calibration and applications of visible imaging cameras on the C-2U advanced beam-driven field-reversed configuration
E M Granstedt1, D Fallah1, M C Thompson1
1TAE Technologies, Inc., 19631 Pauling, Foothill Ranch, California 92610, USA.
Abstract:
Two filtered, fast-imaging instruments, with radial and axial views, respectively, were used on the C-2U device to visualize line emission from impurities and hydrogenic neutrals. Novel calibration techniques needed to be developed for these instruments because the accelerated pace of C-2U operations precluded access to the interior of the vacuum vessel, targets used in typical calibration methods were not available, and in order to account for effects which have not been sufficiently addressed in the literature. Spatial calibration involved optimizing parameters in a generic camera model: ex situ using a checkerboard target and in situ using the vacuum vessel port geometry. Radiometric calibration was performed ex situ in three stages. First, the camera relative response function was mapped using an algorithm developed for high dynamic-range imaging. Second, the non-uniformity of the optical system was measured using a large LCD monitor with a characterized angular emission pattern. Finally, the absolute photon efficiency of each interference filter was determined using a calibrated uniform radiance source while also accounting for reduction in the filter transmission for off-normal rays. Periodically during the run campaign, line emission from neutral beams fired into a gas target was used as an in situ reference to check for degradation of viewport transmission. One application using calibrated camera data was tomographic reconstruction of passive impurity emission, which provided a sanity check to the excluded-flux radius inferred from wall-mounted magnetic sensors.
More Related Videos
05:12Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
Published on: August 12, 2021
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
Related Concept Videos
Induced Electric Fields: Applications
Field Application of Global Positioning System
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...