A Mohan1, G Tharion2, R K Kumar3
1Department of Bioengineering, Christian Medical College Vellore, Vellore, India.
Abstract:
The measurement of hand kinematics is important for the assessment and rehabilitation of the paralysed hand. The traditional method of hand function assessment uses a mechanical or electronic goniometer placed across the joint of interest to measure the range of joint movement. Mechanical goniometers are imprecise and lack the ability to provide a dynamic measurement; electronic goniometers are expensive and cumbersome to use during therapy. An alternative to the goniometric based assessment is to use inertial motion sensors to monitor the hand movement-these can be incorporated in a glove. In this paper, we present the design of an instrumented glove equipped with Magnetic, Angular Rate and Gravity (MARG) sensors for the objective evaluation of hand function. The instrumented glove presented in this paper is designed to assess the range of movement of the hand and also monitor the hand function during the course of hand rehabilitation. Static and dynamic calibrations were performed for the Euler angles calculated from the MARG sensors. The results are also presented for physiological flexion/extension of the wrist (relative roll), flexion/extension of elbow (relative pitch), and internal rotation/external rotation (relative yaw). The static calibration results gave mean absolute errors of 4.1° for roll, 4.0° for pitch, and 4.6° for yaw. From the dynamic calibration, the speed of response to a step change gave a convergence time of 0.4 s; sinusoidally oscillating movement gave good tracking at 0.2 Hz but exhibits overshoot errors at higher frequencies which were tested to be 1 Hz. We present the results of the calibration of the instrumented glove (one sensor pair measuring one joint angle) measuring anatomical joint angles-mean absolute errors during static calibration: 6.3° for a relative roll (wrist flexion/extension), 5.0° for relative pitch (elbow flexion/extension), and 4.5° for relative yaw (shoulder internal rotation/external rotation). The experimental results from the instrumented glove are promising, and it can be used as an alternative to the traditional goniometer based hand function assessments.
More Related Videos
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019
05:58Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Hand hygiene
Hand washing...
Capillary Electrophoresis: Instrumentation