Related Experiment Video
Updated: Feb 3, 2026

Combined Supine and Standing Imaging for Varicocele: An Improved Diagnostic Approach
Published on: November 22, 2024
Combination Doppler backscattering/cross-polarization scattering diagnostic for the C-2W field-reversed configuration
L Schmitz1, B Deng2, M Thompson2
1Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095, USA.
Abstract:
A versatile combination Doppler backscattering and Cross-Polarization Scattering (CPS) diagnostic for the C-2W beam-driven field-reversed configuration is described. This system is capable of measuring density fluctuations and perpendicular magnetic field fluctuations across a wide wavenumber range (2.5 ≤ k θ ρ s ≤ 50), with typical resolution Δk θ/k θ ≤ 0.4-0.8. Four tunable frequencies (26 GHz ≤ f ≤ 60 GHz corresponding to plasma cut-off densities 0.8 × 1019 ≤ n e ≤ 4.4 × 1019 m-3) are launched via quasi-optical beam combiners/polarizers and an adjustable parabolic focusing mirror selecting the beam incidence angle. GENRAY ray tracing shows that the incident O-mode and backscattered CPS X-mode beam trajectories for C-2W plasma parameters nearly overlap, allowing simultaneous detection of ñ and B̃ r or B̃ θ from essentially the same scattering volume.