Related Experiment Video
Updated: Feb 3, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Characterization of photodetector temporal response for neutron time-of-flight (nToF) diagnostics at the National
J M Gordon1, D J Schlossberg2, M J Eckart2
1University of California, Berkeley, Berkeley, California 94720, USA.
Abstract:
The temporal response of a microchannel plate photomultiplier tube used in the suite of neutron time of flight (nToF) diagnostics at the National Ignition Facility has been characterized to reduce uncertainty in, and understanding of, shot parameters obtained from nTOF data. A short pulse laser, neutral density glass filters, and electrical attenuators were used to gather statistically significant samples of photodetector impulse response functions (IRF) in rapid succession. Individual components have been absolutely calibrated to minimize systematic uncertainties. The zeroth (collected charge), first (transit time), and second central moments (transit time spread) of the IRF were calculated as either the bias voltage or the amount of light incident on the detector was varied. Timing reference was provided by a monitor photodiode viewing a pickoff of the incident laser pulse. The primary sources of uncertainty are jitter in the monitor photodiode and the statistical variation across our measurement period. The spreads in the first moment, with respect to the timing photodiode, and the square root of the second central moment were found to be less than 50 ps and 150 ps, respectively.
More Related Videos
07:53Measuring the Time-Evolution of Nanoscale Materials with Stopped-Flow and Small-Angle Neutron Scattering
Published on: August 6, 2021
09:12Functionalization of Single-walled Carbon Nanotubes with Thermo-reversible Block Copolymers and Characterization by Small-angle Neutron Scattering
Published on: June 1, 2016
Related Concept Videos
Design Example: Automobile Ignition System
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
National Nursing Organizations I
National Nursing Organizations II
The AACN emphasizes a healthy work environment through six standards to achieve an optimal patient outcome. The standards are appropriate staffing, meaningful recognition, collaboration, authentic leadership, effective communication, and decision-making. In addition, AACN provides certification programs, webinars, journals, and...
Washing, Drying, and Ignition of Precipitates
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...