Related Experiment Video
Updated: Feb 3, 2026

08:49
External Cephalic Version: Is it an Effective and Safe Procedure?
Published on: June 6, 2020
15.8K
Correction: Do We Need Cephalic Spread of Spinal Anaesthesia for Caesarean Section? A Different Approach to CSE-EVE
L K Fabris1, D Belci1, K Š Zdravčević2
1Department of Anaesthesia and ICU, General Hospital Pula, Pula, Croatia.
Zeitschrift Fur Geburtshilfe Und Neonatologie
|November 8, 2018
Abstract
No abstract available in PubMed .
Related Concept Videos
Cephalic Phase of Digestion
3.8K
The process of digestion is composed of three stages – cephalic, gastric, and intestinal – each with a distinct control center. The cephalic phase is the first stage, and it starts even before the food enters the stomach. It is controlled by the central nervous system and is initiated by any food-related sensory stimuli, such as the sight and smell of food, which send signals to the brain. While eating, the taste receptors intensify these signals, which travel to the cerebral cortex...
3.8K
Spreading of Chromatin Modifications
9.5K
The histone proteins in the nucleosomes are post-translationally modified (PTM) to increase or decrease access to DNA. The commonly observed PTMs are methylation, acetylation, phosphorylation, and ubiquitination of lysine amino acids in the histone H3 tail region. These histone modifications have specific meaning for the cell. Hence, they are called "histone code". The protein complex involved in histone modification is termed as "reader-writer" complex.
Writers
The writer...
Writers
The writer...
9.5K
Distance Corrections
290
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
290
Power Factor Correction
539
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
539
Reducing Line Loss
390
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...