High Performance Seesaw Torsional CMOS-MEMS Relay Using Tungsten VIA Layer

Martín Riverola1, Francesc Torres2, Arantxa Uranga3

  • 1Department of Electronics Engineering, Universitat Autònoma de Barcelona, 08193 Bellaterra, Spain. Martin.riverola@gmail.com.

Micromachines
|November 9, 2018
PubMed

Related Concept Videos

Torsion of Noncircular Members01:16

Torsion of Noncircular Members

Circular shafts undergoing torsional stress maintain their cross-sectional integrity due to their axisymmetric nature. This symmetry ensures an even distribution of stress, allowing the shaft to withstand torsion without distorting. In contrast, square bars, lacking this axial symmetry, experience significant distortion across their cross-sections when subjected to torsion, with the exception of along their diagonals and at lines connecting midpoints. A detailed examination of a cubic element...
581
Torsional Pendulum01:09

Torsional Pendulum

A torsional pendulum involves the oscillation of a rigid body in which the restoring force is provided by the torsion in the string from which the rigid body is suspended. Ideally, the string should be massless; practically, its mass is much smaller than the rigid body's mass and is neglected.
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played...
7.3K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
614
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
540
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
772
Bending and Torsional Moments01:20

Bending and Torsional Moments

Bending and torsional moments are two fundamental concepts in structural engineering. They play an important role in understanding the behavior of materials and structures under different loading conditions.
The reaction developed in a structural element when subjected to an external force causes the element to bend. When a structural element bends upwards, it creates compressive normal forces on the top and tensile normal forces on the bottom, resulting in a couple that determines the bending...
5.8K