Related Experiment Video
Updated: Feb 2, 2026

Diaphragmatic Ultrasound in Adults: Image Acquisition and Interpretation
Published on: January 31, 2025
A New Method for Diaphragmatic Maximum Relaxation Rate Ultrasonographic Measurement in the Assessment of Patients
Christos P Loizou1, Dimitrios Matamis2, Giorgos Minas3
1Department of Electrical Engineering, Computer Engineering and InformaticsCyprus University of Technology3036LimassolCyprus.
Abstract:
Measurements of ultrasound diaphragmatic motion, amplitude, force, and velocity of contraction may provide important and essential information about diaphragmatic fatigue, weakness, or paralysis. In this paper, we propose and evaluate a semi-automated analysis system for measuring the diaphragmatic motion and estimating the maximum relaxation rate (MRR_SAUS) from ultrasound M-mode images of the diaphragmatic muscle. The system was evaluated on 27 M-mode ultrasound images of the diaphragmatic muscle [20 with no resistance (NRES) and 7 with resistance (RES)]. We computed semi-automated ultrasound MRR measurements on all NRES/RES images, using the proposed system (MRR_SAUS = 3.94 ± 0.91/4.98 ± 1.98 [1/s]), and compared them with the manual measurements made by a clinical expert (MRR_MUS = 2.36 ± 1.19/5.8 ± 2.1 [1/s],) and those made by a reference manual method (MRR_MB = 3.93 ± 0.89/3.73 ± 0.52 [1/sec], performed manually with the Biopac system. MRR_SAUS and MRR_MB measurements were not statistically significantly different for NRES and RES subjects but were significantly different with the MRR-MUS measurements made by the clinical expert. It is anticipated that the proposed system might be used in the future in the clinical practice in the assessment and follow up of patients with diaphragmatic weakness or paralysis. It may thus potentially help to understand post-operative pulmonary dysfunction or weaning failure from mechanical ventilation. Further validation and additional experimentation in a larger sample of images and different patient groups is required for further validating the proposed system.
Related Concept Videos
Determination of Michaelis Constant and Maximum Elimination Rate
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
Measuring Reaction Rates
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Maximum Power Transfer
By substituting the entire circuit with...
Maximum Size of Aggregate