The use of optical coherence tomography for the detection of ocular toxicity by ethambutol
Brunella Maria Pavan Taffner1, Felipe Berno Mattos1, Mariana Cartaxo da Cunha1
1Department of Specialized Medicine, Division of Ophthalmology, Hospital das Clínicas of the Federal University of Espírito Santo, Vitória, Espírito Santo, Brazil.
Objectives:
To evaluate, through (OCT), alterations in retinal thickness, secondary to use of ethambutol in the treatment of patients with tuberculosis. In addition to studying the use of simpler semiological tools, such as Amsler and Ishihara, in the screening of these cases.
Methods:
Thirty patients with ethambutol were recruited from the reference service of tuberculosis treatment at the Federal University of Espírito Santo from May 2015 to July 2016. After clinical history, the following parameters were analyzed; best corrected visual acuity, biomicroscopy, tonometry, photomotor reflex testing, Ishihara test, Amsler's grid test, color digital retinography and optical coherence tomography with CIRRUS HD-OCT (Humphrey-Zeiss) every 2 months during treatment with ethambutol. They were divided into two groups according to the treatment: (1) standard group, two months of ethambutol; (2) extended group, nine to twelve months of ethambutol.
Results:
There was a significant reduction in OCT thickness between the pre and post treatment times in ten eyes of the extended group, mean reduction of 7,8 microns and in seven eyes of the standard group, with an average of 5.57 microns. During the study, a significant reduction of retinal thickness was observed in both groups at two months of treatment, and the delta percentage was higher in those patients who presented reduction of visual acuity and / or change in the Ishihara test.
Conclusion:
There was a significant reduction in the thickness of the nerve fiber layer by OCT in the patients studied, being more pronounced in those submitted to the extended treatment regimen. This reduction was observed two months after the start of therapy, and was more significant in the cases that presented changes in the Ishihara test.
Related Concept Videos
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Properties of Enantiomers and Optical Activity
Imaging Studies III: Computed Tomography
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...