Measurement reliability of phonation threshold pressure in pediatric subjects
Matthew R Hoffman1, Austin J Scholp1, Calvin D Hedberg1
1Department of Surgery, Division of Otolaryngology-Head and Neck Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, U.S.A.
Objectives/Hypothesis:
Phonation threshold pressure (PTP), the minimum subglottal pressure (Ps ) required for phonation, is sensitive to changes in laryngeal biomechanics and is often elevated with pathology. Little is reported on PTP in children; challenges with task performance and measurement reliability represent barriers to routine clinical assessment.
Study Design:
Pilot study evaluating PTP and Ps measurement reliability in children using labial and mechanical interruption.
Methods:
Twenty-two subjects aged 4 to 17 years (10.7 ± 3.9 years) participated. Ten trials were performed for each method; task order was randomized. For labial interruption, subjects produced /pα/ five times at softest (onset PTP) and comfortable amplitude. For mechanical interruption, subjects produced a sustained /α/ while a balloon valve interrupted phonation five times for 250 ms each; mechanical interruption was performed with a mouthpiece and mask. PTP was recorded as the difference between Ps and supraglottal pressure at phonation cessation (offset PTP). Mean PTP and Ps and intrasubject coefficients of variation were compared. Correlations with age were evaluated.
Results:
Mean PTP (P < .001) and Ps (P = .005) were higher for labial interruption. Intrasubject coefficients of variation for PTP (P = .554) and Ps (P = .305) were similar across methods. Coefficient of variation was related to age for mechanical-mask trials only (r = -0.628, P = .00175).
Conclusions:
Differences in means are likely related to differences in task and PTP hysteresis effect. Reliability is comparable with all methods; using a mouthpiece may be preferable to a mask for mechanical interruption. Measurement of PTP is noninvasive, reliable, and may be a useful adjunct in pediatric voice assessment.
Level Of Evidence:
3b Laryngoscope, 129:1520-1526, 2019.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Reliability and Validity
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.