Objectives:
Novel automated computed tomography (CT) software (Valve ASSIST 2) has been developed for transcatheter aortic valve implantation (TAVI), which not only provides three-dimensional (3D) reconstruction of multidetector (MD) CT images, but also enables intraprocedural real-time fusion of fluoroscopic and MDCT images. We aimed to clarify the reproducibility and accuracy of this software in the aortic annulus assessment and verify the potential of intraprocedural integrated MDCT imaging for TAVI.
Methods And Results:
We examined 50 patients with severe aortic stenosis undergoing transfemoral TAVI. Aortic annulus measurements were performed using 3mensio and the novel planning software. For intraprocedural imaging, preoperative CT dataset was overlaid onto fluoroscopy with the fusion software. The two images were aligned using the aortic root anatomy visible on both modalities. Novel planning software provided excellent reproducibility for the measurement of aortic annulus area (intraobserver intraclass correlation coefficients [ICC] 0.959, interobserver ICC 0.941), and perimeter (intraobserver ICC 0.915, interobserver ICC 0.912). Excellent correlation was found between novel planning software and 3mensio (ICC 0.952 for aortic annulus area, and 0.923 for perimeter). Intraprocedural fusion image of CT aortography and fluoroscopic aortic root aortography generated by this novel software identified coronary orifices and the distribution of aortic valve calcification during the device positioning. Fusion image displayed coronary orifices after device implantation.
Conclusions:
Novel planning software showed excellent reproducibility and accuracy in the assessment of aortic root anatomy. Furthermore, the integrated 3D fusion image might have a potential as an intraprocedural imaging modality to contribute to the development of a safer TAVI procedure.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Applications of Integration to Find Centers of Mass
Statistical Software for Data Analysis and Clinical Trials
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...