New postoperative conduction abnormalities after the implantation of a rapid-deployment aortic valve prosthesis
Christian Mogilansky1, Robert Balan1, Cornelia Deutsch2
1Department of Cardiac Surgery, Klinikum Passau, Passau, Germany.
Objectives:
Sutureless and rapid-deployment aortic valves have enlarged the selection of prostheses available for surgical aortic valve replacement. However, the rate of postoperative pacemaker implantation seems to have increased.
Methods:
In addition to pacemaker implantation, we were interested in the incidence of new postoperative conduction abnormalities, namely left bundle branch block, right bundle branch block and atrioventricular block III after the implantation of the EDWARDS INTUITY Elite™ sutureless prosthesis. All patients undergoing isolated or concomitant surgical aortic valve replacement between May 2014 and May 2017 were included in the study.
Results:
Two hundred patients were operated on. Of them, 14 patients dropped out because of concomitant endocardial or epicardial ablation or because of septal myectomy. Three more patients dropped out because the treatment was converted to conventional aortic valve replacement, and 183 patients remained. At the time of discharge from hospital, 38.1% of the 183 patients had new left bundle branch block, 2.5% of patients had new right bundle branch block and 9.6% had atrioventricular block III requiring either a pacemaker or defibrillator. The postoperative mean transvalvular gradient over the prosthesis was 8.4 ± 3.4 mmHg, the occurrence of paravalvular leakage more than trivial was 1% and hospital mortality was 3.3%.
Conclusions:
The incidence of new postoperative conduction abnormalities is considerable with the EDWARDS INTUITY Elite rapid-deployment aortic valve prosthesis. We will focus our future research on the follow-up of patients with postoperative left bundle branch block, which was the most frequently observed form of new conduction abnormality.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Abnormal Proliferation
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduct Disorder
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...