Related Experiment Video
Updated: Feb 2, 2026

Subjective Refraction Test Using a Smartphone for Vision Screening
Published on: October 18, 2024
Agreement and Repeatability of Two Biometers to Measure Anterior Segment Components: Refractive Error Effect
Alberto Domínguez-Vicent1, Rune Brautaset1
1Unit of Optometry, Department of Clinical Neuroscience, St. Erik Eye Hospital, Karolinska Institutet, Stockholm, Sweden.
Abstract:
BACKGROUND To assess the repeatability and agreement between a new high-resolution optical coherence tomographer (OCT) and a Scheimpflug topographer. MATERIAL AND METHODS Sixty phakic and healthy participants were measured in this study, and one eye per participant was analyzed. Depending on their refractive error, each participant was allocated into a myopic, hyperopic, or emmetropic group. The Cirrus HD-OCT 5000 (Carl Zeiss Meditec, Jena, Germany), and the Sirius Scheimpflug topographer (Costruzione Strumenti Oftalmici, Florence, Italy) were used to take all measurements. RESULTS The repeatability of these instruments to measure the anterior chamber depth, angle-to-angle, thinnest pachymetry, and both nasal and temporal angles was smaller than 0.15 mm, 0.40 mm, 10 µm, and 10 degrees, respectively. However, the repeatability of the Scheimpflug instrument to measure the apex pachymetry was about 15 µm, and for the OCT, it was about 4 µm for all groups. On average, the Sirius Scheimpflug instrument measured shallower anterior chamber depth (about 0.10 mm), shorter angle-to-angle (about 0.5 mm), thinner corneas (approximately 10 µm), and narrower angles (around 5 degrees) for all refractive groups. CONCLUSIONS The repeatability of the Cirrus OCT and Sirius Scheimpflug instrument was good and independent of the refractive error. Nevertheless, to judge whether these instruments could be used interchangeable, clinical criteria are needed.
More Related Videos
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Random Error
Margin of Error
Standard Error of the Mean
The standard error of the mean is an example of a standard error. It is a unique standard deviation known as the standard deviation of the sampling distribution of the mean. The standard error of the mean is a statistic that calculates how correctly a sample distribution represents a...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...

